SFRplus Chart on Photographic Paper QI-SFR10-P-RM

This SFRplus Chart on Photographic Paper QI-SFR10-P-RM Instrument are Certified with
certify
1 Years Warranty (Additional support period of 3 years)

The SFRplus test chart can be used with the SFRplus module in Imatest 3.2 or later to measure MTF, lateral chromatic aberration, distortion, and tonal response. The SFRplus module features fully automated region-of-interest detection.

The SFRplus chart offers significant advantages over commonly used charts such as the ISO 12233 chart, including

  1. much less wasted area,
  2. The ability to produce a map of sharpness over the sensor surface,
  3. better measurement accuracy due to the lower contrast,
  4. full support for automated testing.


SFRplus charts on photographic paper have the following properties:

  • 5x9 grid pattern
  • Active Area: 223mm x 356mm. It is recommended these charts be used to test imaging systems with sensors up to 3 MP. For larger image sensor sizes, please see other SFRplus chart listings. The active area of the chart includes white space above and below the top and bottom distortion bars. It is typically about 10% larger than the printed area, which is bounded by the distortion bars on top and bottom. White space is included because test images of the chart must include this white space in order to enable automated processing in SFRplus software.
  • Contrast levels: 10:1 and 2:1 contrast levels to analyze non-linear signal processing

Our Valued Clients

FAQs About  SFRPlus Test Charts

There is no generic mathematical formula for gloss value. Rather, it is measured directly with a gloss meter, which compares how strongly reflected light from a sample matches a standard (typically black glass with a known reflectance).


A haze meter is precise and accurate if the sample is clean, there is a light contamination, and the sample is condition.


A powder coated surface is most commonly measured for thickness post curing using a digital coating thickness gauge. This method is non-destructive, helps verify coverage uniformity and meets quality control standards. A powder comb gauge is used to estimate thickness for a pre-cured coating.

There are three measuring apertures for NH310: Φ8mm (standard accessory), Φ4mm (standard accessory), extended Φ8mm (optional accessory)

a. Turning on

b. Removing measuring aperture, install the needed measuring aperture.

c. Select "Settings-Aperture Setting" in main menu to select corresponding measuring aperture.

d. After selecting aperture, the instrument will display "White and Black Calibration" interface. White and black calibration must be performed.

e. Replace completed.

Once ignited, the gauge will select the correct substrate mode. The probe should be placed flat on the coated surface. The thickness of the coating will show on the screen. Measurements should be taken on different areas of the surface to ensure accuracy.


For wallpaper color consistency & quality control (including solid-color, printed, textured, and embossed wallpapers), these 3nh spectrophotometers deliver optimal performance:


1. TS8560 Benchtop (Lab & R&D – Best Accuracy)

  • d/8° integrating sphere, SCI/SCE dual mode

  • ΔE*ab ≤ 0.01 (repeatability), IIA ≤ 0.1

  • Multi-apertures (Φ3/8/15/25mm) — ideal for large patterned wallpapers

  • UV control (for optical brighteners in paper)

  • Best for: Lab formulation, color standardization, batch-to-batch consistency

  • TS8560 Benchtop instrument


2. TS7700 Portable (Production & Field)

  • d/8° (SCI/SCE), ΔE*ab ≤ 0.02

  • Handheld, fast, non-destructive

  • Large aperture (Φ20mm) averages out texture/pattern unevenness

  • Best for: Production line checks, warehouse incoming inspection, on-site matching

  • TS7700 Portable spectrophotometer instrument

3. PS2080 Portable (Textured/Patterned Wallpapers)

  • d/8°, interchangeable apertures (Φ4/8mm + 1×3mm)

  • High stability for rough/embossed surfaces

  • UV included for fluorescent inks/papers

  • Best for: Complex printed, textured, or metallic-effect wallpapers

  • PS2080 Portable spectrophotometer

4. NS800 (Cost-Effective Routine QC)

  • 45/0 geometry, ΔE*ab ≤ 0.04

  • Touchscreen, easy operation

  • Best for: Uniform solid-color wallpapers, basic production QC

  • NS800 Hand Held Spectrophotometer

Short Recommendation

  • Top lab precision: TS8560

  • Best portable production: TS7700

  • Best for textured/patterned: PS2080

  • Economical routine QC: NS800

All ensure stable, repeatable color measurement for wallpaper rolls, panels, and printed patterns.


Related SFRPlus Test Charts You May Also Like

Give us a call!

Discuss your project with one of our product specialists:

0086 755 26508999

Need pricing?

We respond to quote requests within 1 business day.

service@3nh.com

Already know what you need?

Submit a demo request for the product you're interested in.

Get a Demo
Leave Your Message
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Privacy policy