ISO 12233:2014 Edge SFR(eSFR)Test chart

This ISO 12233:2014 Edge SFR(eSFR)Test chart Instrument are Certified with
certify
1 Years Warranty (Additional support period of 3 years)

SineImage ISO 12233:2014 E-SFR charts are implementations of the Low Contrast Edge SFR (E-SFR) test chart illustrated in Section 6.1 and Annex Cof the ISO Standard Document. The charts come in three versions:

  • Standard: basic, no extra measurement features

  • Enhanced: extra squares, wedges, and color patterns when printed with technologies that allow color

  • Extended: similar to Enhanced, but with a 16:9 aspect ratio, suitable for HDTV and cinema

We currently offer these charts in inkjet format, with Enhanced versionsavailable as photographic prints. All SineImage ISO 12233:2014 E-SFR charts are fully compliant with the ISO standard. The Imatest eSFR ISO moduleprovides highly automated support for the new charts.
 

Details


Chart Size Standard Enhanced Extended
1x 200 mm × 305 mm
7.875" × 12"
200 mm × 305 mm
7.875" × 12"
200 mm × 365 mm
7.875" × 14.5"
2x 400 mm × 610 mm
15.75" × 24"
400 mm × 610 mm
15.75" × 24"
400 mm × 730 mm
15.75" × 29"
4x 800 mm × 1220 mm
31.5" × 48"
800 mm × 1220 mm
31.5" × 48"
800 mm × 1460 mm
31.5" × 58"

Standard Version

 
Standard Version

This chart, which has a 3:2 aspect ratio, is a "no-frills" implementation of the standard. For most work we recommend the Enhanced or Extended charts, which have additional edges for measuring performance near the image boundaries, as well as hyperbolic wedges and color patches (where the technology allows). These chartsmaintain full compliance with the standard.

The Imatest Standard ISO 12233:2014 E-SFR chart closely resembles the Low contrast E-SFR test chart illustrated in section 6.1 and Annex C of the ISO standard document, with a few differences, all of which are fully compliant with the ISO standard.

  • A 20 patch OECF grayscale pattern* is used instead of the 16 patch version.
  • The Focus Patterns in the centers of the squares are rectangular (to increase the MTF measurement area) and are designed to reduce interference with automatic edge detection.
  • There are four registration marks instead of three to facilitate automated region detection. (Four features are required for a projective transform.)
  • An additional mark above the lower-left registration mark is used for detecting chart orientation.

Enhanced Version

 

Enhanced Version

The Imatest Enhanced ISO 12233:2014 E-SFR chart has all the features of the Standard chart, keeping the 3:2 aspect ratio, with the addition of six added slanted squaresfor measuring performance near the image boundaries and hyperbolic wedges for visual analysis or analysis with the Imatest Wedge module. It also has 16 color patches when produced with technologies that allow color. Since these additions are in regions of the chart not covered by the standard, compliance with the standard is unaffected.

The differences between the Imatest charts and the chart illustrated in the standard are listed below. Even with these differences the Imatest chart is in full compliance with the standard.

  • A 20 patch OECF grayscale pattern* is used as opposed to the 16 patch version.
  • The Focus Patterns in the centers of the squares are rectangular (to increase the MTF measurement area) and are designed to reduce interference with automatic edge detection.
  • There are four registration marks instead of three to facilitate automated region detection. (Four features are required for a projective transform.)
  • An additional mark above the lower-left registration mark is used for detecting chart orientation.
     

The differences between the Enhanced and Standard Versions are as follows:

  • Six extra slanted squares are added for measuring performance near the image boundaries.
  • Several hyperbolic wedges with spatial frequencies, similar to the CIPA chart referenced in the ISO standard, for visual analysis or use with the Imatest Wedge module.
  • 16 color patches when produced with technologies that allow color (inkjet or color LVT), with colors similar to the industry-standard 24-color test chart.
     

This chart will work with the fully-automated eSFR ISO module.

 

Extended Version

 

Extended Version

The Imatest Extended ISO 12233:2014 E-SFR chart has all the features of the Enhanced chart (six extra squares, wedges, and 16 color patches where possible), but has a16:9 aspect ratio, which makes it suitable for HDTV and cinema measurements (and it also works well with 3:2 aspect ratio DSLRs). It is fully compliant with the standard.

This chart will work with the fully-automated eSFR ISO module.

Our Valued Clients

FAQs About  ISO Test Charts

Measurement Accuracy (dE/ΔE): The smaller the value, the higher the match between the color measured by the colorimeter instrument and human visual perception. Generally, dE < 1.0 is regarded as the industrial passing line, while dE < 0.5 falls into the high-precision level. 

Measurement Structure: D/8 (integrating sphere structure) is the universal standard, which includes two modes: SCI (Specular Component Included, with specular reflection light) and SCE (Specular Component Excluded, excluding specular reflection light). 45/0 (ring illumination) simulates the human eye's viewing angle and is more suitable for judging reflective materials. 

Repeatability: It refers to the difference in color results when measuring the same point multiple times. The equipment can achieve ΔE < 0.08, ensuring highly reliable measurement results. 

Illumination Source and Viewing Angle: It is recommended to choose the combination of CIE standard light source D65 (simulating daylight) and a 10° viewing angle. 

Application Scenario Requirements: It is necessary to clarify the purchase purpose (quality inspection? R&D? material evaluation?) and the usage environment (laboratory, workshop or field work?).


A haze meter should be calibrated every 6 months, or more frequently if used for certain quality control processes.


Threenh Technology with excellent after sale service, Generally, Our warranty is one years(Additional support period of 3 years). Within the warranty period, we can offer technique support and parts to parts change, necessarily, our engineers may go to your place for better support. Our instrument have professional After-sales Dept. lf you have any technical problem or question with our goods welcome to contact us.

Standard light sources make sure that the results of color evaluations are comparable and consistent, no matter when and where the assessments are made, or the varying production runs.


This refers to assessing samples with a specific color and maintaining the same alloted time interval on all parameters to ensure neutrality of variables and reproducibility of lightness in the color. 


In the study of chemical reactions, calorimetry deals with changes in heat (energy and enthalpy). Spectrophotometry is the measurement of the light absorbance or light transmittance to determine the concentration or color of a solution. The first one monitors the thermal processes, whereas the second one addresses the aspects of light and color.


Related ISO Test Charts You May Also Like

Give us a call!

Discuss your project with one of our product specialists:

0086 755 26508999

Need pricing?

We respond to quote requests within 1 business day.

service@3nh.com

Already know what you need?

Submit a demo request for the product you're interested in.

Get a Demo
Leave Your Message
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Privacy policy