Contact Our Specialists

Types of 3NH Dynamic Range Charts Products

Our Valued Clients

FAQs About  Dynamic Range Charts

A light booth for color matching usually contains D65 (daylight), TL84 (store), A (incandescent) and UV light. LED may also be used in modern time for additional color matching. 


The main instruments used to detect color are spectrophotometers and colorimeters (including photoelectric integrating colorimeters). 

Spectrophotometer: High-precision option. It analyzes the full visible light spectrum to measure color accurately. Suitable for complex scenarios like textured surfaces, special effect colors, or batch consistency checks in industries such as paint and coatings. 

Colorimeter (Photoelectric Integrating Colorimeter): Cost-effective and portable. It uses RGB filters to measure tristimulus values directly. Ideal for quick color difference detection in simple applications. Key Selection Tip Choose based on accuracy needs: use a spectrophotometer for high-precision color measurement, and a colorimeter for fast, basic color difference checks.


Threenh colorimters are used across various industries to measure, analyze, and control color accuracy and consistency:

Food and Beverages: Monitor color quality in food products to meet industry standards.

Plastics and Polymers: Ensure color uniformity in plastic components (e.g., casings, buttons, panels) during manufacturing.

Chemicals and Pharmaceuticals,Cosmetics: Industry-specific accessories to attain the highest safety protocols, Ensure uniform color in pharmaceutical products for quality and brand recognition;Develop and match colors for cosmetics (e.g., lipsticks, creams, powders) and ensure batch consistency.

Textiles and Apparel: Monitor color consistency in fabrics during dyeing, printing, or finishing processes; ensure color consistency in fabrics and garments.

Building materials, Paints, and Coatings: Detect color deviations in coatings on metal, wood, or plastic surfaces (e.g., automotive paints, furniture finishes). Maintain color accuracy in building materials, paints, and coatings.

Printing and Packaging: Validate color accuracy in printed materials (e.g., brochures, labels, packaging) against design proofs, maintain consistency across different printing technologies.

By addressing color-related quality control challenges, 3NH colorimeters help industries maintain brand consistency, meet regulatory standards, and enhance customer satisfaction.


During color evaluation, maintaining consistent light sources and viewing conditions is critical. Standard viewing conditions vary depending on the object being evaluated, including factors such as brightness, illumination angle, and observer position. Accurate evaluation can be achieved by establishing a proper environment that meets these requirements.

In development and production sites with extremely high color requirements, such as the automotive and cosmetics industries, accurately reproducing colors is essential. Color evaluation helps determine whether the color matches the intended image or target color. It is the process of measuring color, analyzing its characteristics, and evaluating how well it aligns with a specific target color. 

color measurement and color evaluation

Visual Color Evaluation

Color differences are compared visually using standard light sources or reference colors (such as color cards). This method allows color confirmation under conditions close to natural light, making it ideal for color inspection in design and production processes. 

Instrumental Color Evaluation

Measurements are performed using a spectrophotometer or colorimeter. This method eliminates the subjective influence of the operator and is widely used for product quality control and industrial applications, enabling scientific quantification of color.


Color evaluation is widely used across industries such as product development and quality control departments in manufacturing. 

Typical applications include: 

  • Automotive Industry

    Used for quality evaluation of automotive paint, exterior parts, and interior components.

  • Coatings & Materials Industry

    Used to maintain and manage color accuracy for coatings, plastics, glass products, and more.

  • Cosmetics Industry

    Used to verify color consistency in products such as lipsticks and foundations.

  • Molded Products (Resin & Plastics)

    Used to evaluate color difference and uniformity of surface effects in finished products.

  • Furniture & Building Materials Industry

    Used to ensure color consistency in materials such as wood and plywood. Food & Pharmaceutical Industry Used to assess color consistency of food packaging and color differences in pharmaceutical capsules.

A benchtop spectrophotometer is not universally better—it outperforms portable units in precision and lab testing, while portable models win for on-site flexibility. Which one is better depends entirely on your testing scenarios, accuracy requirements and workflow.


Benchtop Spectrophotometer Advantages

  • Higher measurement accuracy & repeatability, excellent inter-instrument agreement

  • Supports full-spectrum analysis, more geometric optical designs

  • Larger testing aperture, compatible with curved, textured and bulk samples

  • Ideal for laboratory QC, R&D, formula matching and standard color calibration

  • Stable performance, less affected by external light and environment


Portable Spectrophotometer Advantages

  • Compact, lightweight, test anywhere anytime (production line, warehouse, on-site inspection)

  • Fast one-click measurement, no fixed power and lab space required

  • Perfect for incoming material inspection, on-line production spot check, field color comparison

  • Lower cost and easier to operate for frontline workers


Which One Should You Choose?


Choose benchtop if you need:

Lab R&D, high-precision color grading, standard sample database establishment, strict quality control for cosmetics, plastics, textiles and food.


Choose portable if you need:

On-site rapid detection, production line mobile sampling, outdoor and on-location color measurement.


To operate the haze meter, first calibrate the instrument, clean the sample, position it correctly in the holder, and initiate the measurement. The instrument then shows the haze and overall transmittance readings.

Further Dynamic Range Charts Applications and Solutions

Become a Distributor
Become a Distributor

We are available from monday to friday to answer your questions
Assure responding within 24 hours

Contact US
Contact US

Need to contact us? Just send us an e-mail at service@3nh.com

Give us a call!

Discuss your project with one of our product specialists:

0086 755 26508999

Need pricing?

We respond to quote requests within 1 business day.

service@3nh.com

Already know what you need?

Submit a demo request for the product you're interested in.

Get a Demo
Leave Your Message